Investigation of optimum secondary fan location and air quantity to control DPM recirculation in underground dead-end workings

Journal Article


Abstract


  • This paper presents a detailed study on optimising the location of auxiliary fans to control DPM-air recirculation in dead-end workings in which diesel-operated vehicles are used. Parametric studies using computational fluid dynamics (CFD) models validated against field measurements are presented. The study consists of varying the fan locations from the dead-end crosscut and varying the intake air quantities using a 30 m3/s capacity two-stage 75 kW auxiliary fan. The results showed that if the drive intake air flow rate matches the fan capacity (30 m3/s), recirculation will occur even when the fan is located 10 m away from the crosscut entry. Results also showed that if the intake drive air quantity was greater than or equal to 150% of fan capacity (≥45 m3/s), no recirculation was observed when the fan location was at least 5 m away from the dead-end crosscut access.

Publication Date


  • 2021

Citation


  • Morla, R., Karekal, S., Godbole, A., Shriwas, M., Chapula, B., & Jacobs, J. (2021). Investigation of optimum secondary fan location and air quantity to control DPM recirculation in underground dead-end workings. International Journal of Mining and Mineral Engineering, 12(3), 195-205.

Scopus Eid


  • 2-s2.0-85120810041

Web Of Science Accession Number


Start Page


  • 195

End Page


  • 205

Volume


  • 12

Issue


  • 3

Abstract


  • This paper presents a detailed study on optimising the location of auxiliary fans to control DPM-air recirculation in dead-end workings in which diesel-operated vehicles are used. Parametric studies using computational fluid dynamics (CFD) models validated against field measurements are presented. The study consists of varying the fan locations from the dead-end crosscut and varying the intake air quantities using a 30 m3/s capacity two-stage 75 kW auxiliary fan. The results showed that if the drive intake air flow rate matches the fan capacity (30 m3/s), recirculation will occur even when the fan is located 10 m away from the crosscut entry. Results also showed that if the intake drive air quantity was greater than or equal to 150% of fan capacity (≥45 m3/s), no recirculation was observed when the fan location was at least 5 m away from the dead-end crosscut access.

Publication Date


  • 2021

Citation


  • Morla, R., Karekal, S., Godbole, A., Shriwas, M., Chapula, B., & Jacobs, J. (2021). Investigation of optimum secondary fan location and air quantity to control DPM recirculation in underground dead-end workings. International Journal of Mining and Mineral Engineering, 12(3), 195-205.

Scopus Eid


  • 2-s2.0-85120810041

Web Of Science Accession Number


Start Page


  • 195

End Page


  • 205

Volume


  • 12

Issue


  • 3