Fission converter and metal-oxide-semiconductor field effect transistor study of thermal neutron flux distribution in an epithermal neutron therapy beam

Journal Article


Abstract


  • The depth distribution of the thermal neutron flux is a major factor in boron neutron capture therapy (BNCT) in determining the efficiency of cell sterilization. In this paper the fission detector method is developed and applied to measure the in-phantom thermal neutron flux depth distribution. Advantages of the fission detector include small size, direct measurement of thermal neutron flux in a mixed radiation field of BNCT beam, self- calibration, and the possibility of on-line measurement. The measurements were performed at epithermal a BNCT facility. The experimental results were compared with the thermal neutron flux calculated by the Monte Carlo method and found to be in good agreement.

Publication Date


  • 1999

Citation


  • Kaplan, G. I., Rosenfeld, A. B., Allen, B. J., Coderre, J. A., & Liu, H. B. (1999). Fission converter and metal-oxide-semiconductor field effect transistor study of thermal neutron flux distribution in an epithermal neutron therapy beam. Medical Physics, 26(9), 1989-1994. doi:10.1118/1.598703

Scopus Eid


  • 2-s2.0-0032828494

Start Page


  • 1989

End Page


  • 1994

Volume


  • 26

Issue


  • 9

Abstract


  • The depth distribution of the thermal neutron flux is a major factor in boron neutron capture therapy (BNCT) in determining the efficiency of cell sterilization. In this paper the fission detector method is developed and applied to measure the in-phantom thermal neutron flux depth distribution. Advantages of the fission detector include small size, direct measurement of thermal neutron flux in a mixed radiation field of BNCT beam, self- calibration, and the possibility of on-line measurement. The measurements were performed at epithermal a BNCT facility. The experimental results were compared with the thermal neutron flux calculated by the Monte Carlo method and found to be in good agreement.

Publication Date


  • 1999

Citation


  • Kaplan, G. I., Rosenfeld, A. B., Allen, B. J., Coderre, J. A., & Liu, H. B. (1999). Fission converter and metal-oxide-semiconductor field effect transistor study of thermal neutron flux distribution in an epithermal neutron therapy beam. Medical Physics, 26(9), 1989-1994. doi:10.1118/1.598703

Scopus Eid


  • 2-s2.0-0032828494

Start Page


  • 1989

End Page


  • 1994

Volume


  • 26

Issue


  • 9