Skip to main content
placeholder image

Dry sliding wear behaviour of full pearlite obtained by cladding low carbon steel to hypoeutectoid steel

Journal Article


Abstract


  • The dry sliding wear behaviour of the full pearlite in a novel bimetal consisting of low carbon steel and hypoeutectoid steel has been studied by means of pin-on-disc type wear tests at room temperature. Thermomechanical treatments were performed on the bimetallic samples to obtain different interlamellar spacings. It was found that interlamellar spacing decreased with an increase in plastic strain to a great extent initially and followed by a lower extent of decrease. This decrease not only increases the hardness and strain hardening capacity of the fully pearlitic microstructure, but also is in favor of stabilizing the friction coefficient during sliding process. The observations of wear tracks show that delamination dominated the wear process when interlamellar spacing is higher than 200 nm, while pronounced oxidational wear occurred with interlamellar spacing below 200 nm.

UOW Authors


  •   Gao, Xingjian (external author)
  •   Jiang, Zhengyi
  •   Wei, Dongbin
  •   Kosasih, Buyung B.
  •   Jiao, Sihai (external author)
  •   Chen, Dengfu (external author)

Publication Date


  • 2014

Citation


  • Gao, X., Jiang, Z., Wei, D., Kosasih, B., Jiao, S. & Chen, D. (2014). Dry sliding wear behaviour of full pearlite obtained by cladding low carbon steel to hypoeutectoid steel. Advanced Materials Research, 1017 147-153.

Scopus Eid


  • 2-s2.0-84913540420

Ro Metadata Url


  • http://ro.uow.edu.au/eispapers/3257

Number Of Pages


  • 6

Start Page


  • 147

End Page


  • 153

Volume


  • 1017

Abstract


  • The dry sliding wear behaviour of the full pearlite in a novel bimetal consisting of low carbon steel and hypoeutectoid steel has been studied by means of pin-on-disc type wear tests at room temperature. Thermomechanical treatments were performed on the bimetallic samples to obtain different interlamellar spacings. It was found that interlamellar spacing decreased with an increase in plastic strain to a great extent initially and followed by a lower extent of decrease. This decrease not only increases the hardness and strain hardening capacity of the fully pearlitic microstructure, but also is in favor of stabilizing the friction coefficient during sliding process. The observations of wear tracks show that delamination dominated the wear process when interlamellar spacing is higher than 200 nm, while pronounced oxidational wear occurred with interlamellar spacing below 200 nm.

UOW Authors


  •   Gao, Xingjian (external author)
  •   Jiang, Zhengyi
  •   Wei, Dongbin
  •   Kosasih, Buyung B.
  •   Jiao, Sihai (external author)
  •   Chen, Dengfu (external author)

Publication Date


  • 2014

Citation


  • Gao, X., Jiang, Z., Wei, D., Kosasih, B., Jiao, S. & Chen, D. (2014). Dry sliding wear behaviour of full pearlite obtained by cladding low carbon steel to hypoeutectoid steel. Advanced Materials Research, 1017 147-153.

Scopus Eid


  • 2-s2.0-84913540420

Ro Metadata Url


  • http://ro.uow.edu.au/eispapers/3257

Number Of Pages


  • 6

Start Page


  • 147

End Page


  • 153

Volume