MRI-Guided-PT: Integrating an MRI in a proton therapy system

Conference Paper


Abstract


  • © CYC 2019.All rights reserved. Integration of magnetic resonance imaging (MRI) in proton therapy (PT) has the potential to improve tumor-targeting precision. However, it is technically challenging to integrate an MRI scanner at the beam isocenter of a PT system due to space constraints and electromagnetic interactions between the two systems. We present a concept for the mechanical integration of a 0.5 T MRI scanner (MR-Open, ASG Superconductors) into a PT gantry (ProteusONE, IBA). Finite element modelling (FEM) simulations are used to assess the perturbation of several of the gantry's elements on the homogeneity of the scanner's static magnetic field. Results show that only the perturbations by the bending magnet are significant and to be taken into account during treatment planning and dose delivery.

Authors


  •   van der Kraaij, E (external author)
  •   Smeets, J (external author)
  •   Bertora, L (external author)
  •   Carrozzi, A (external author)
  •   Serra, A (external author)
  •   Oborn, Brad M.
  •   Gantz, Sebastian (external author)
  •   Hoffmann, Aswin (external author)
  •   Karsch, L (external author)
  •   Lühr, A (external author)
  •   Pawelke, J (external author)
  •   Schellhammer, Sonja M. (external author)

Publication Date


  • 2020

Citation


  • van der Kraaij, E., Smeets, J., Bertora, L., Carrozzi, A., Serra, A., Oborn, B., Gantz, S., Hoffmann, A., Karsch, L., Lühr, A., Pawelke, J. & Schellhammer, S. (2020). MRI-Guided-PT: Integrating an MRI in a proton therapy system. CYC 2019 - Proceedings of the 22nd International Conference on Cyclotrons and their Applications (pp. 145-148). JACoW Publishing.

Scopus Eid


  • 2-s2.0-85086012749

Start Page


  • 145

End Page


  • 148

Abstract


  • © CYC 2019.All rights reserved. Integration of magnetic resonance imaging (MRI) in proton therapy (PT) has the potential to improve tumor-targeting precision. However, it is technically challenging to integrate an MRI scanner at the beam isocenter of a PT system due to space constraints and electromagnetic interactions between the two systems. We present a concept for the mechanical integration of a 0.5 T MRI scanner (MR-Open, ASG Superconductors) into a PT gantry (ProteusONE, IBA). Finite element modelling (FEM) simulations are used to assess the perturbation of several of the gantry's elements on the homogeneity of the scanner's static magnetic field. Results show that only the perturbations by the bending magnet are significant and to be taken into account during treatment planning and dose delivery.

Authors


  •   van der Kraaij, E (external author)
  •   Smeets, J (external author)
  •   Bertora, L (external author)
  •   Carrozzi, A (external author)
  •   Serra, A (external author)
  •   Oborn, Brad M.
  •   Gantz, Sebastian (external author)
  •   Hoffmann, Aswin (external author)
  •   Karsch, L (external author)
  •   Lühr, A (external author)
  •   Pawelke, J (external author)
  •   Schellhammer, Sonja M. (external author)

Publication Date


  • 2020

Citation


  • van der Kraaij, E., Smeets, J., Bertora, L., Carrozzi, A., Serra, A., Oborn, B., Gantz, S., Hoffmann, A., Karsch, L., Lühr, A., Pawelke, J. & Schellhammer, S. (2020). MRI-Guided-PT: Integrating an MRI in a proton therapy system. CYC 2019 - Proceedings of the 22nd International Conference on Cyclotrons and their Applications (pp. 145-148). JACoW Publishing.

Scopus Eid


  • 2-s2.0-85086012749

Start Page


  • 145

End Page


  • 148