Skip to main content
placeholder image

Heat transfer analysis of an integrated double skin facade and phase change material blind system

Journal Article


Download full-text (Open Access)

Abstract


  • In this study, the heat transfer in an integrated double skin facade (DSF) and phase change material (PCM) blind system has been theoretically analysed. Both heat transfer and airflow models with CFD methods have been developed for the integrated DSF and PCM blind system. Data from an existing typical DSF building have been obtained in order to define input parameters for the simulation exercise and validate the numerical models. The temperature and velocity fields in DSF with the PCM blind system has been predicted under overheating scenario using the ANSYS Workbench FLUENT software and been compared with case of conventional aluminium blind system. This study has shown that the integrated PCM blind system was able to reduce the average air temperature and outlet temperature of the DSF while improving the convective heat transfer between the cavity air and the blades. Compared with the aluminium blind, the PCM blind can absorb large amount of excessive heat in the cavity. Overall the integrated PCM blind system has the potential to be used as an effective thermal management device for minimising the overheating effect in DSFs.

Publication Date


  • 2017

Citation


  • Li, Y., Darkwa, J. & Kokogiannakis, G. (2017). Heat transfer analysis of an integrated double skin facade and phase change material blind system. Building and Environment, 125 111-121.

Scopus Eid


  • 2-s2.0-85028638981

Ro Full-text Url


  • http://ro.uow.edu.au/cgi/viewcontent.cgi?article=1623&context=eispapers1

Ro Metadata Url


  • http://ro.uow.edu.au/eispapers1/622

Number Of Pages


  • 10

Start Page


  • 111

End Page


  • 121

Volume


  • 125

Place Of Publication


  • United Kingdom

Abstract


  • In this study, the heat transfer in an integrated double skin facade (DSF) and phase change material (PCM) blind system has been theoretically analysed. Both heat transfer and airflow models with CFD methods have been developed for the integrated DSF and PCM blind system. Data from an existing typical DSF building have been obtained in order to define input parameters for the simulation exercise and validate the numerical models. The temperature and velocity fields in DSF with the PCM blind system has been predicted under overheating scenario using the ANSYS Workbench FLUENT software and been compared with case of conventional aluminium blind system. This study has shown that the integrated PCM blind system was able to reduce the average air temperature and outlet temperature of the DSF while improving the convective heat transfer between the cavity air and the blades. Compared with the aluminium blind, the PCM blind can absorb large amount of excessive heat in the cavity. Overall the integrated PCM blind system has the potential to be used as an effective thermal management device for minimising the overheating effect in DSFs.

Publication Date


  • 2017

Citation


  • Li, Y., Darkwa, J. & Kokogiannakis, G. (2017). Heat transfer analysis of an integrated double skin facade and phase change material blind system. Building and Environment, 125 111-121.

Scopus Eid


  • 2-s2.0-85028638981

Ro Full-text Url


  • http://ro.uow.edu.au/cgi/viewcontent.cgi?article=1623&context=eispapers1

Ro Metadata Url


  • http://ro.uow.edu.au/eispapers1/622

Number Of Pages


  • 10

Start Page


  • 111

End Page


  • 121

Volume


  • 125

Place Of Publication


  • United Kingdom